Urgent Closed Repair Requests

See Also: All Closed Repair Requests at Benning Elementary School

Detailed Reports

Urgent Closed Repair Requests
Description Open Date Close Date Time Elapsed
FM-200116024 01 9/17/01 BENNING BOILER ROOM 1. ASBESTOS ASSESSMENT REQUIRED. 2. REPLACE INSULATION ON FRON DOORS OF BOILER #1 & 2. INSULATION ON BOILER DOORS DID NOT PASS BOILER INSPECTION. CODE A-CLEAR FOR REPAIR BY DCPS SAFETY CEB 8/6/01 July 27, 2001 September 17, 2001 52 days
FM-200116268 01 9/25/01 (BENNING) FIRE CODE VIOLATION: F-610.2 PAGE (3 OF 4) 1ST FLOOR: EXIT SIGN OUT. ASBESTOS CODE A - CLEAR FOR REPAIRS ON 09/04/01. RONALD EDWARDS - SAFETY (202)576-6693 (RG) July 31, 2001 September 25, 2001 56 days
FM-200108299 01 11/27/01 BENNING OUTSIDE - FRONT OF BUILDING TREE ROOTS MAKING SIDEWALK UNLEVEL. SAFETY HAZARD. April 12, 2001 November 27, 2001 229 days
FM-200206178 02 5/24/02 Benning ****Urgent**** Outside Exterior Drain Replace drain cover & clear backup. The drain is by the entry/exit door on the playground side. April 22, 2002 May 24, 2002 32 days
FM-200213556 02 8/20/02 (Benning) ***Very Very Urgent*** Back of building/Next to football field: Unstop two (2) main drains; with stagnant water standing. Please respond, as this area is a haven for mosquitos and other insects. August 5, 2002 August 20, 2002 15 days
FM-200202610 02 3/19/03 (BENNING) PLAYGROUND A LIGHT POLE IS LEANING & NEEDS TO BE STRAIGHTENED & SECURED OR REMOVED (SAFETY ISSUE) February 7, 2002 March 19, 2003 405 days
FM-200227566 03 3/26/03 (Benning) !!!VERY URGENT!!! Learning Center #1: Unable to unstop sink in the girls bathroom; appears to be a problem in the junction line. 03/26/03: call came in from engineer stating, water is coming out the sink, flooding the floors. March 24, 2003 March 26, 2003 2 days
FM-200335002 03 8/13/03 Benning Playground A large light pole fell down on the back playground. It need to be removed. (SAFETY HAZARD) August 13, 2003 August 13, 2003 0 days
FM-200337412 03 9/16/03 (Benning) !!!URGENT!!! Ground Floor Kitchen/Cafeteria: Repair or replace lock on supply room door; key will not turn cylinder. Asbestos Code A - Clear for repairs on 09/12/03. Horne Engineering - Sheryll James (RG 09/15/03) September 12, 2003 September 16, 2003 4 days
FM-200335200 03 10/1/03 Benning There are fifteen light poles which need to come down. Its a safety hazard. One light pole has already fallen. August 14, 2003 October 1, 2003 48 days
FM-200225170 03 11/7/03 Benning Large evergreen trees from the park side of the school fence, is leaning over onto the school side of the fence. Dropping large pieces of limbs and branches, and when the tree fall it will knock down a large outside light. It is a safety problem for the students. Repair fence and cut down some of the tree hanging over the fence. February 4, 2003 November 7, 2003 276 days
FM-200335815 03 1/13/04 Benning New locks on two safety doors in the multi service room and computer door in officeand book (1) and book 2 need new lock. August 20, 2003 January 13, 2004 146 days
FM-200452372 04 8/20/04 Benning Fire Code Violation Second floor Ceiling tile missing in front of all purpose room. Asbestos Code A - Clear for repairs on 08/12/04. DCPS Safety - Richard Gibson (RG) August 12, 2004 August 20, 2004 8 days
FM-200452370 04 8/20/04 Benning Fire Code Violation Second floor Ceiling tile missing in bookroom # 2. Asbestos Code A - Clear for repairs on 08/12/04. DCPS Safety - Richard Gibson (RG) August 12, 2004 August 20, 2004 8 days
FM-200332557 03 9/20/04 (Benning) !!!URGENT!!! Playground: Install sump pump; drains are unable to handle the amount of water coming into the building from the playground. June 26, 2003 September 20, 2004 452 days
FM-200452373 04 11/10/04 Benning Fire Code Violation First floor Exit door in need of repair in kitchen. Asbestos Code A - Clear for repairs on 08/30/04. DCPS Safety - Richard Gibson (RG 08/31/04) August 12, 2004 November 10, 2004 90 days
FM-200457439 /04 12/3/04 Benning Pre K Mrs. Johnson Pre-K back door need repairing or replacing on upper bar. Asbestos Code A - Clear for repairs on 08/28/04. DCPS Safety -Leroy Minton Jr. (RG 08/29/04) October 26, 2004 December 3, 2004 38 days
FM-200456655 04 8/1/05 Benning Exit door in need of repair in kitchen. Asbestos Code A - Clear for repairs on 10/08/04. DCPS Safety - Richard Gibson (RG) October 8, 2004 August 1, 2005 297 days
FM-200457441 /04 8/12/05 Benning Office room Metal door multi purpose will not close need lining up. Asbestos Code A - Clear for repairs on 10/26/04. DCPS Safety - Richard Gibson (RG) October 26, 2004 August 12, 2005 290 days
FM-200457443 /04 8/16/05 Benning Ground floor Lunchroom door need repairing or replacing on upper bar. Asbestos Code A - Clear for repairs on 10/26/04. DCPS Safety - Richard Gibson (RG) October 26, 2004 August 16, 2005 294 days
FM-200507934 05 8/16/05 (Benning) "Fire Code Violation" Second floor. Kindergarden exit door not closing properly. (IFC1003.3.1) Asbestos Code A - Clear for repairs on 07/19/05. DCPS Safety - Richard Gibson (RG) July 15, 2005 August 16, 2005 32 days
FM-200216544 02 10/20/05 Benning Asbestos Assessment Reqd. Pre-Kindergarten Replace ceiling tiles in the kindergarten area. Asbestos Code A - Clear for repairs on 09/05/02. DCPS Safety - Leroy Minton Jr. (RG 09/06/02) September 4, 2002 October 20, 2005 1,142 days
FM-200216541 02 10/20/05 Benning Asbestos Assessment Reqd. Lunchroom Ceiling in the lunchroom is leaking oil, which may be coming from the roof. Asbestos Code A - Clear for repairs on 09/05/02. DCPS Safety - Leroy Minton Jr. (RG 09/06/02) September 4, 2002 October 20, 2005 1,142 days
FM-200332590 03 12/14/05 Benning !! Very Urgent !! Exterior - Play Ground ( west side ) 1. Unclog exterior drains - water is coming in the building . June 26, 2003 December 14, 2005 902 days
FM-200508084 05 12/29/05 (Benning) "Fire Code Violation" Second floor. Ceiling tile missing (Pre K) (IFC 110.1) Asbestos Code A - Clear for repairs on 07/20/05. DCPS Safety - Richard Gibson (RG) July 19, 2005 December 29, 2005 163 days
FM-200517063 06 1/4/06 Very Urgent: First Floor-Main Office-Repair the outside window it's loose from the frame. January 3, 2006 January 4, 2006 1 day
FM-200517061 06 1/4/06 Main Entrance - Replace broken window. Urgent !! January 3, 2006 January 4, 2006 1 day
FM-200508049 05 1/10/06 (Benning) "Fire Code Violation" Second floor. Ceiling tile missing (Migrant Education) (IFC 110.1) Asbestos Code A - Clear for repairs on 07/19/05. DCPS Safety - Richard Gibson (RG) July 19, 2005 January 10, 2006 175 days
FM-200458750 /04 1/26/06 Benning Kitchen Need to replace tiles on kitchen floor. Have everything you need at the school, just come. Asbestos Code A - Clear for repairs on 01/13/05. DCPS Safety - Leroy Minton Jr. (RG 01/14/05) November 29, 2004 January 26, 2006 423 days
FM-200113153 01 2/3/06 BENNING PLAYGROUND 1 & 2 1) BIG DRAIN CLOGGED UP ON PLAYGROUND ASBESTOS CODE A - CLEAR FOR REPAIRS ON 11/03/01. RICHARD GIBSON- SAFETY (202)576-5584(RG) June 12, 2001 February 3, 2006 1,697 days
FM-200120476 01 2/3/06 (BENNING) ASBESTOS ASSESSMENT REQ. 1ST FLOOR/ KITCHEN REPLACE HEATING COIL IN DOUBLE SINK COMPARTMENT. ASBESTOS CODE A - CLEAR FOR REPAIRS ON 10/25/01. LEROY MINTON - SAFETY (202)576-6691 (RG) September 25, 2001 February 3, 2006 1,592 days
FM-200618774 06 6/30/06 Benning Boiler Room Boiler #2 Replace leaking relief valve and bottom blow down valve. Urgent !!!!! February 17, 2006 June 30, 2006 133 days
FM-200625582 06 8/18/06 Benning Boiler Room Unclog drain in boiler room floor Urgent !!!!! July 12, 2006 August 18, 2006 37 days
FM-200221568 /02 8/25/06 BENNING Boiler room 1. Asbestos assessment may be required. 2. Replace 8 " OS&Y valve on hot water supply that is not holding. Asbestos Code A-clear for repair by Horne Engineer Philip Connolly DCPS Safety Charles E. Buchanan on 11/26/02 November 25, 2002 August 25, 2006 1,369 days
FM-200631546 /06 12/13/06 Benning Boiler Room Repair or replace safety relief valve on Boiler #1. Watts Valve; Model M; Size 1-1/4 lb; Set 30 lbs #740 October 31, 2006 December 13, 2006 43 days
FM-200626262 06 1/16/07 1st Floor- Main Office Replace door checks in the main office, and shave one door (it swells and will not open). Asbestos Code A - Cleared for repairs on 08/02/06 by Tidewater/Kenny Long (LM-08/02/06) Safety Office 202-576-8962. July 24, 2006 January 16, 2007 176 days
FM-200617469 06 1/19/07 Urgent: Office-Repair or replace front door Asbestos Code A - Clear for repairs on 01/17/06. Tidewater - Henry Addison (RG 01/17/06) January 17, 2006 January 19, 2007 367 days
FM-200515181 05 1/19/07 Urgent: R/R door in the Pre-K area, its broken. Asbestos Code A - Clear for repairs on 11/10/05. Tidewater - Rodney Distance (RG 11/14/05) November 7, 2005 January 19, 2007 438 days
FM-200445423 04 1/22/07 Benning Throughout building Eighteen (18) doors need new door check. The check can not be adjusted. The doors slam causing them to be a safety hazard. Asbestos Code A - Clear for repairs on 03/17/04. Horne Engineering - Bipin Nanavaty (RG 03/19/04) March 16, 2004 January 22, 2007 1,042 days
FM-200338788 /03 3/7/07 Benning Basement The electrical panel in the electric room need to be disconnected, because the light pole is being taken down for safety reason. Asbestos Code A - Clear for repairs on 10/14/03. Horne Engineering - Troy Wilcome (RG 10/22/03) October 10, 2003 March 7, 2007 1,244 days
FM-200500304 05 3/7/07 Benning Area in fron of school main doors have unenev concrete and someone will bump into it and injury them self. January 11, 2005 March 7, 2007 785 days
FM-200501219 05 3/7/07 Benning Stairways Repair Lighting on steps Asbestos Code A - Clear for repairs on 02/04/05. DCPS Safety - Richard Gibson (RG) February 4, 2005 March 7, 2007 761 days