Open Repair Requests: July 2004

See Also: All Open Repair Requests at Woodson High School

July 2004 Summary

  • Urgent Requests
    2
  • Routine Requests
    18
  • Total Requests
    20

Detailed Reports

Urgent Repair Requests Opened in July 2004 (2)
Description Open Date
FM-200450575 7/21/04 Woodson,H.D. Throughout Building SAFETY Insulate the following areas: Room #105,#201,#202,#207,#209,#210,#303,#307,#401,#501,#606,#710,#711-(8" OSY valve) Pool area, Music room,Book room, Cafeteria and Principal office closet. Code A-clear for repair by DCPS Charles Buchanan 8/16/04 July 21, 2004
FM-200450923 7/28/04 Woodson, H.D. Room #202 #303 and Library Asbestos assessment required On insulation on pipe in room#303, #202 and Library area and over hing plaster ceiling. No asbestos impact to ceiling inthese room 202, 303, & library. HA 008 Placter & Ceiting NAD HA 708 Brown Coat with HA 008 NAD Code A-clear for repair by DCPS Charles Buchanan on 8/16/04 Code 'C' Re-assigned -- (Abatement of asbestos tar coumpond must be conducted within the Library univent; an exploratory investigation must be conducted above plaster ceiling over hang). DCPS Safety, R. Edwrards -- 8/16/04. Code A - asbestos abated on 08/20/04 per DCPS Safety Ronald Edwards confirmed. ( RG 08/24/04) July 28, 2004

Routine Repair Requests Opened in July 2004 (18)
Description Open Date
FM-200450110 7/7/04 Woodson, H.D. Swimming Pool Check swimming pool, pool is dumping. July 7, 2004
FM-200450011 7/8/04 Woodson, H.D. Room 203 Clean and paint 655 SF wall and door frame. Replace (6) stained and buckled 2'x4' ceiling tile. Provide and install (5) new door stops. Patch 5"x9" hole in base glazed wall tile under classroom clock. Provide and install (9) wall mounted outlets at location designed by school principle. Replace light fixture (3) rows 20' Long 4' sections 2 bulbs. Repair (4) lower window sections to make them operational so that they will open and close properly. Remove (1) 6'-6" high x 3' wide x 1'-6" wide metal storage cabinet and replace with new. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450012 7/8/04 Woodson, H.D. Room 204 Clean and paint 33 SF of walls above air conditioning unit. Replace 32 SF of stained and bukled 2'x4' ceiling tiles. Remove 3 rows of 20' long 4' section, 2 bulb pendent type light fixtures and replace with new. Provide and install new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Provide and install 14 gauges painted metal enclosure 9'-10 1/2" high to cover exposed vertical plumbing lines. Repair 4 lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning units. Replace existing 3'x7' hollow core entry door with security door painted with new hardware and kick plates. Remove 246 SF of movable partition and replace with painted drywall with vinyl base. Also, include in drywall outlets to accomodate 9 computers. Replace 2 outlet cover plates. Cover plate under black board projects 1/8" from face of wall needs filler. Other plate needs to be oversized to rough opening. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450033 7/8/04 Woodson, H.D. Room 205 Clean and paint 717 SF of walls and trim. Replace 48 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Repair (5) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall air conditioning unit. Remove 246 SF pf movable partition and replace with painted drywall with vinyl base. Also, include in drywall outlets to accomodate 9 computers. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450034 7/8/04 Woodson, H.D. Room 206 Clean and paint 679 SF of walls and trim. Replace 48 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Repair (4) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning unit. Remove 242 SF pf movable partition and replace with painted drywall with vinyl base. Also, include in drywall outlets to accomodate 9 computers. Replace existing 3' x 7' entry door with new security door painted with hardware. Provide missing duplex wall cover plate. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450035 7/8/04 Woodson, H.D. Room 207 Clean and paint 772 SF of walls and trim. Replace 136 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Repair (3) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning unit. Remove 242 SF of folding partition and replace with painted drywall with vinyl base. Also, include in drywall outlets to accomodate 9 computers. Replace existing 3' x 7' entry door with new security door painted with hardware. Provide missing duplex wall cover plate. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450037 7/8/04 Woodson, H.D. Room 208 Clean and paint 51 SF walls over mounted air conditioning unit and door frame. Replace 80 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Repair (4) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning unit. Replace existing 3' x 7' entry door with new security door painted with hardware. Remove (1) 8' long x 3' high x 2'-6" wide laboratory vanity cabinet. Cap all service lines (water and gas). Provide and install wall mounted outlet to accommodate 9 computers at location designated by the school principle. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450038 7/8/04 Woodson, H.D. Room 209 Clean and paint 719 SF of walls and door frame in classroom. Clean and paint 352 SF of walls and door frame in teacher office. Replace 80 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Repair (5) lower sections of windows to make them operational so that they will open and close properly. Replace entry door closure. Clean and service wall mounted air conditioning unit. Provide and install wall mounted outlets to accommodate 9 computers at location designated by school principle. Replace 3 laboratory goose neck faucets. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450039 7/8/04 Woodson, H.D. Room 210 Clean and paint 719 SF of walls and door frame in classroom. Clean and paint 352 SF of walls and door frame in teacher office. Replace 88 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Remove (1) 6'-6" high x 3' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. Repair (1) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning unit. Provide and install wall mounted outlets to accommodate 9 computers at location designated by school principle. Replace 3 laboratory goose neck faucets. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450040 7/8/04 Woodson, H.D. Room 302 NOTE: The following line item will be deleted from this service order per request of Mr. Vigil Colemen, Project manager, PD&C, "Replace existing 12'-2 1/2" x 4'-2" caulk board with new.". The remaining items are cleared for repairs. R. Edwards 9/10/04 Replace 144 SF of stained and buckled 2'x4' ceiling tiles. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Repair (1) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning unit. Provide and install wall mounted outlets to accommodate 9 computers at location designated by school principle. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450041 7/8/04 Woodson, H.D. Room 303 Clean and paint 101 wall and door frame trim. Replace 80 SF of stained and buckled 2'x4' ceiling tiles. Provide and install new 3' x 7' security door with hardware that will allow the door to swing into classroom. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (1) new door stop. Repair (1) lower sections of windows to make them operational so that they will open and close properly. Provide and install 2 duplex cover plates. Repair lock on face panel cover to wall air conditioning unit to allow secure closing. Clean and service wall mounted air conditioning unit. Provide and install wall mounted outlets to accommodate 9 computers at location designated by school principle. Provide and install window shades sizes 2'-11" wide x 7' long and 4'-3" wide x 7' long. Remove (1) 6'-6" high x 3 ' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450042 7/8/04 Woodson, H.D. Room 305 NOTE: The following line item will be deleted from this service order per request of Mr. Vigil Colemen, Project manager, PD&C, "Replace existing 12'-2 1/2" x 4'-2" caulk board with new.". The remaining items are cleared for repairs. R. Edwards 9/10/04 Clean and paint replace 910 SF wall, door frame and store front office. Replace 80 SF of stained and buckled 2'x4' ceiling tiles. Remove 2 rows 24' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (6) new door stop. Repair (3) lower sections of windows to make them operational so that they will open and close properly. Clean and service wall mounted air conditioning unit. Provide and install wall mounted outlets to accommodate 14 computers at location designated by school principle. Replace temporary plywood enclosure (1) 1'-6" x 2' painted metal panel. Remove 11'-2" long x 5'-8" high display case to accommodate its opening from the classroom instead of the corridor. Remove (1) 6'-6" high x 3 ' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450043 7/8/04 Woodson, H.D. Room 312 NOTE: The following line item will be deleted from this service order per request of Mr. Vigil Colemen, Project manager, PD&C, "Replace window glazing in teacher's conference area (2'-10 1/2" x 4'-11") and classroom (4'-11" x 4'-2") and Remove (15) floor outlets and cover with plates.". The remaining items are cleared for repairs. R. Edwards 9/10/04 Clean and paint 44 SF plaster wall over wall air conditioning unit door. Clean and paint 708 SF of CMU wall in teacher's conference area, office and door frames. Remove 3 rows 20' long 4 ' section, 2 bulbs pendent type light fixtures and replace with new. Provide and install (2) new door stop. Clean and service wall mounted air conditioning unit. Provide and install wall mounted outlets to accommodate 14 computers at location designated by school principle. Replace temporary plywood enclosure (1) 1'-6" x 2' painted metal panel. Remove 11'-2" long x 5'-8" high display case to accommodate its opening from the classroom instead of the corridor. Remove (1) 6'-6" high x 3 ' wide x 1'-6" deep metal teacher's storage cabinet and replace with new. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450006 7/8/04 Woodson, H.D. Room 200 NOTE: The following line item will be deleted from this service order per request of Mr. Vigil Colemen, Project manager, PD&C, "Remove 450 SF existing carpeting and refinish 570 SF of existing tile floor.r". The remaining items are cleared for repairs. R. Edwards 9/10/04 Clean and paint 506 SF of wall and door frame. Replace 104 SF of stained and buckled 2'x4' ceiling tile. Provide and install (5) new door stops. Remove (2) temporary plywood panels and install (2) new metal 1'-11"x2" -8" section panels in store front trim. Repair leaking thermostat. Clean and service (4) wall air conditioning units. Provide and install (4) wall mounted outlets at location designed by school principle. Clean and paint exterior/interior metal office storefront trim. 6'-7"x9', 11'-9" x 9' and 11'-5"x 9'. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450008 7/8/04 Woodson, H.D. Room 200A NOTE: The following line item will be deleted from this service order per request of Mr. Vigil Colemen, Project manager, PD&C, "Remove 299 SF of existing carpeting and refinish 299 SF of existing tile floor". The remaining items are cleared for repairs. R. Edwards 9/10/04 Replace (80) of stained and buckled 2'x4' ceiling tile. Provide and install new door stop. Clean and paint 144 SF of CMU back wall and door frame. Repair leaking thermpstat. Provide and install (4) wall mounted outlets at location designed by school principle. Replace (2) 4' long bulbs. Repair an 11"x11" opening in plaster over interior of entry door. Remove (2) 42"Hx18"Dx42"W metal file cabinets and replace with (3) rows of 42" Long shelving to match existing. Clean and service below ceiling mounted air conditioning unit. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450010 7/8/04 Woodson, H.D. Room 201 Clean and paint 85 SF of plaster walls over wall air conditioning unit. Clean and paint 497 SF of CMU walls column and door frame. Replace 120 SF stained and buckled 2'x4' ceiling tile. Remove 3 rows of 20' long 4' section, 2 bulb pendent type light fixtures and replace with new. Provide and install new door stop. Remove 42 SF of wall mounted cabinet above laboratory counter and paint. Provide wall mounted outlets to accommodate (6) computers at locations designated by the school principle. Replace existing 3'-7' hollow core wood door to backroom (teacher copy area) and replace with security doors with hardware. Remove wooden drawers from wall mounted base cabinet at (2) locations and replace with (2) 1'-6 1/2"x 2'-7" painted plywood facing to match existing color. Replace existing entry door lock and lock plates. Remove 297 SF of movable partition and replace with drywall painted with 6" vinyl base. Drywall shall include wall outlets to accommodate 2 computers. Remove (1) 8' long x 4' wide x3' high laboratory cabinet that is located in front of the wall mounted base cabinet. Remove (1) 6'-10" high x 2'-11" wide x 2' deep laboratory cabinet. Repair 4 lower window sections to make them operational so that they will open and close properly. Clean and service wall air conditioning units. Rework 5'-9"x5'-8" display case to accomodate its opening from the class room instead of the corridor. HA 005 Ceiling tile white 2x4 Pinhole and divots in a circular pattern No ACM HA 008 Plaster white on wall and and celling No ACM HA 708 Brown Coat with HA 008 No ACM HA 056 Fire Door ...ACM Code A-clear for repair by Charles Buchanan on 7/14/04 July 8, 2004
FM-200450623 7/22/04 Woodson, H.D. Repair or replace drip pan in univent. Rooms #202,#209,#303, Book room, Music room and Auditorum AHU July 22, 2004
FM-200451151 7/30/04 Woodson H.D. Check and make correction chiller is not cooling. July 30, 2004