Urgent Open Repair Requests
See Also: All Open Repair Requests at Johnson JHS
Detailed Reports
| Description | Open Date |
|---|---|
| FM-200204558 8 3/18/02 (Johnson) Asbestos Assessment Required Basement Near Cafeteria Replace missing glazed block near univent in hallway [safety hazard]. Repair missing glaze block near univen in hallway. Code A-clear for repair by Horne Engineer ( Z Mahmood ) on 3/19/02 (CEB | |
| FM-200209667 7 6/17/02 (Johnson Jr.) ***Emergency*** 4th Floor Stairwell: Due to break-in, skylight broke and hanging from the ceiling; staff concerned with skylight falling to the floor. (Safety hazard) | |
| FM-200210230 6/25/02 Johnson ****Urgent**** 1. Asbestos Assessment Reqd. 1st, 3rd & 4th Floors 2. Repair or install dedicated breakers to support the a/c units, because breakers are tripping in the following rooms, when the a/c is on: 1st floor library, room 154, nursing office, 102, 103, counselor's suite A100, principal's office & main office; 3rd floor rooms 302, 303 & 315; 4th floor rooms 401, 402 & 404. The high heat is affecting staff that is working in the above-listed areas. units are on: Code A-clear for repair by Horne Engineer ( Bipin Nanavaty ) on 06/26/02 | |
| FM-200224730 1/28/03 Johnson Urgent Safety Hazard !!! D Wing near auditorium 1) Roof leaks has affected ceiling in D- Wing corridor near the auditorium and D-12. Two large sections of ceiling is loss and about to fall in. Asbestos Code A - Clear for repairs 02/21/03. Horne Engineering - Troy Wilcome (RG 02/24/03) | |
| FM-200228391 4/7/03 Johnson - URGENT Exterior grounds Unstop outside drain of library on patio. Basement is floded due to this drain. | |
| FM-200331964 6/17/03 Johnson !! URGENT !! Exterior 1. Unstop three storm drains around the building - standing water . | |
| FM-200333268 7/15/03 (Johnson) !!!VERY URGENT!!! Roof Top: Skylight broken by vandals. Call came in approx. 3:20 p.m. | |
| FM-200340293 11/14/03 (Johnson Jr.) !!!VERY URGENT!!! 2nd Floor/Room #233: Window pulled away from the frame, attempting to fall; due to heavy winds. | |
| FM-200444257 2/19/04 (Johnson) !!!VERY URGENT!!! Basement Level/Managers/Staff Restroom: After flushing toilet, water began too come through floor. (Very large amount of water on floor) | |
| FM-200447896 5/13/04 (Johnson) !!!VERY URGENT!!! Main Entrance/Front of Building: Strip that holds window glass in place has been removed; appears that vandals trying to enter. This is a safety hazard, as glass could fall, and injure staff/students. | |
| FM-200451361 8/3/04 Johnson Exhaust fan motors - (Needed- 4) Furnish four (4) exhaust fan motors for service on roof in Gym areas. Two (2) motors ME Electric, Model 5 QK 480L7,D104E,RPM-1725, PH -1, V-115,48-3FR, 4A,1/4 HP, 4.6A. Two (2) motors Maraton ME Electric HP-1/2, Model 56T17D44, 5VW, RPM-1725, V 230/460 P113, Cy 60 Urgent !!!!! | |
| FM-200451362 8/3/04 Johnson PE Office-Electric Electrican needed to hook up or run wires for service to exhaust fan in PE Office of Gym. Urgent !!!!! | |
| FM-200451364 8/3/04 Johnson Roof Area AHU #55 Repair shaft on Air Handler Unit #55 over Gym Area on rooftop. Urgent !!!!! | |
| FM-200453174 8/23/04 Johnson Second floor room 220 Hand sink in room hanging off the wall need to be fixed. Asbestos Code A - Clear for repairs on 08/23/04. DCPS Safety - Leroy Minton Jr. (RG 08/23/04) | |
| FM-200456038 9/29/04 Johnson Girls locker room area Restore electrical service to univents, recepticals, & exhaust fans. Asbestos Code A - Clear for repairs on 09/29/04. DCPS Safety - Richard Gibson (RG) | |
| FM-200459949 12/21/04 Johnson JHS URGENT Repair ruptured line in room 301 | |
| FM-200502534 3/10/05 [Johnson} "Urgent" Third floor, room 315. Repair or Replace broken window in room in room 315. 03/10/2005 14:37 MJF - | |
| FM-200502723 3/15/05 (Johnson) "Emergency" Fourth floor/Room 421. Repair and Replace large wire mesh glass in classroom. Note: Student vandalized. Asbestos Code A - Clear for repairs on 03/30/05. DCPS Safety - Leroy Minton Jr. (RG 03/30/05) | |
| FM-200503565 4/5/05 (Johnson) Second, Third and Fourth floors. Replace broken windows in rooms 226, 315 and 413. Code A- clear for repairs as of 4/15/05 Sylvia Grimes safety | |
| FM-200505588 5/17/05 ( JOHNSON ) URGENT!!!! First, Second, Third, and Fourth Floor - Boys and Girsl Restrooms 1) Need asbestos assessment for all restrooms Code A-clear for repair by DCPS Charles Buchanan on 5/ 20/05 | |
| FM-200506193 6/1/05 ( JOHNSON ) URGENT!!! Classroom 312 1) Replace wire mesh glass to door entrance. | |
| FM-200506506 6/8/05 ( JOHNSON ) B Wing - Head Start, Room 104 1) Need two air conditioners installed in two windows. Asbestos Code A - Clear for repairs on 06/09/05. DCPS Safety - Leroy Minton Jr. (RG 06/09/05) | |
| FM-200508842 7/27/05 (Johnson) "Urgent" Head Start B Wing. Repair or Replace A/C unit. A/C unit shut off and will not come on. Note: Staff checked electrical box breaker had not been tripped. | |
| FM-200510542 8/17/05 (Johnson) "Urgent" First floor. Repair or Replace water fountain, water is leaking all over the floor (a fast drip) | |
| FM-200512390 9/12/05 Johnson Urgent (safety hazard) Basement-Elevator Shaft Pump out water from elevator shaft, water has a meldew smell. | |
| FM-200512391 9/12/05 Johnson Urgent First Floor-Water Cooler Next to Elevator Repair/Replace cooler that is leaking water down the elevator shaft and on the floor. | |
| FM-200512608 9/15/05 Johnson Emergency Third Floor-Rm. 318 Cap off gas line flush to the floor, the pipe is sticking up 36" from the floor, a stove was removed. "Safety Hazard" | |
| FM-200512615 9/15/05 Johnson Second Floor-Classroom 220 Replace wire-mesh safety glass in window of room 220 student vandalized. | |
| FM-200512617 9/15/05 Johnson First Floor-Near Library Replace wire-mesh safety glass in exit door window by library | |
| FM-200513634 10/7/05 Johnson Urgent First Floor-Rm. 105 Repair hole in the ceiling. Asbestos Code A - Clear for repairs on 10/13/05. Tidewater - Rodney Distance (RG 10/14/05) | |
| FM-200515942 12/1/05 First fl Stairwell near Gym EMERGENCY!!!! URGENT!!!!!! Repair Skyllight glass Asbestos Code A - Clear for repairs on 12/05/05. Tidewater - Tony Marcolin (RG 12/08/05) | |
| FM-200515961 12/1/05 Urgent:Vandalism: Repair the followig water fountains: 4th Fl. near rms. 416, elevator-leaking, and 411-filter needed 3rd Fl. near rms. 303-remount on the wall, 312-low water pressure, and 318-leaking 2nd Fl. near rms. 220-stopped up, and elevator-leaking 1st Fl. near elevator-leaking, nurse office not working, rm. 107 (D wing) stopped up and Gym-2 broken | |
| FM-200516007 12/2/05 "Urgent" 1.) Repair locks on the following classroom doors, 416, 411, 419, 424, 422, 326, 312, 313, 319, 318, 324, 212 and 214. 2.) Repair or Replace door knob locks and lock cover plates in the following rooms 405, 422, 313, 314,319, to prevent students from breaking into the classrooms. Note: The majority of the damage was cause through vandalism. | |
| FM-200516784 12/20/05 Urgent: Replace cylinder that has fallen out of the door to the vault across from the gym. The key was broken in the lock. | |
| FM-200619663 3/8/06 Urgent Fourth Floor-Room 422 Door entrance wire mesh glass window broken/student vandalized. Asbestos Code A - Clear for repairs on 03/09/06. Tidewater - Henry Addison (RG 06/05/06) | |
| FM-200619667 3/8/06 Urgent Third Floor-Room 315 Door entrance wire mesh glass window broken/student vandalized. | |
| FM-200619918 3/14/06 Urgent Water cooler was removed from wall. Pipe is leaking. Line was capped off but not holding-Water is all over the floor. | |
| FM-200619919 3/14/06 Urgent Basement, First, Second, and Third Floors Service all water fountains, they are leaking. | |
| FM-200620333 3/24/06 Basement, Second & Third Floors. "Urgent" 1.) Basement floor, unstop toilet in custodian's office on basement level. 2.) Second floor, remount sink on wall in boys' restroom & unstop custodian's slop sink in second floor custodian's closet. 3.) Third floor, unstop sink in teachers' restrooom & unstop custodian's slop sink in third floor custodian's closet. | |
| FM-200621040 4/6/06 Basement-Unstop lavatories on the basement level in the custodian foreman and boiler plant operator offices. Toilet backs up when the commodes are flushed. (Very Urgent) | |
| FM-200631915 11/7/06 Third Floor - Classroom 324 - Replace wire mesh safety glass in entrance door. Asbestos Code A - Clear for repairs on 11/09/06. Tidewater - Cornell Parks (RG 11/15/06) | |
| FM-200700204 2/4/07 KITCHEN - Urgent - Repair or replace hot water heater in kitchen. | |
| FM-200701998 3/16/07 Location: 3rd Floor Mens Bathroom (Very Urgent) Sink Clogged up and can not wash their hands. | |
| FM-200702001 3/16/07 Location: 1st Floor Health Suite (Very Urgent) Sink clogged up and the children can not wash their hands. | |
| FM-200702201 702201 3/19/07 Location: 1st Floor Room: Auditorium Very Urgent Principal needs a ligh bulb replaced in the auditorium. Room is very dark. Black History Assembly March 13/07. |