Closed Repair Requests: March 2003
See Also: All Closed Repair Requests at Ballou Senior High School
March 2003 Summary
Detailed Reports
| Description | Open Date | Close Date | Time Elapsed |
|---|---|---|---|
| FM-200120675 01 3/25/03 BALLOU 1 ST FLOOR REGESTRA ROOM REPLACE (1) ONE SAFETY RELIEF VALVE ON BOILER #1 INFO: 2" RELIEF VALVE MOD# 174A 30 LBS. ASBESTOS CODE A-CLEAR FOR REPAIR 10/12/01 BY HORNE ENGINEER STEPHEN CALDWELL |
| Description | Open Date | Close Date | Time Elapsed |
|---|---|---|---|
| FM-200218628 02 3/19/03 Ballou Ground floor - Locker room Re-install lumber for seats. (Three benches are broken) | |||
| FM-200219128 02 3/19/03 Ballou Outside - Football field Weeds growing in bleachers need to be removed. Grass areas on the sides of the bleachers and along the fence line A. | |||
| FM-200114434 01 3/19/03 BALLOU OUTSIDE - SOUTHWEST - END OF BUILDING HANDICAPP RAMP IS NEEDED AT THE SOUTHWEST END OF THE BUILDING. THIS IS IN COMPLIANCE WITH ADA CODE. | |||
| FM-200100461 01 3/19/03 BALLOU BOYS SHOWER ROOM HOLES IN BOYS SHOWER GR-20000150 | |||
| FM-200100075 01 3/19/03 BALLOU AROUND ENTIRE BUILDING PRUNE TREES AROUND ENTIRE BUILDING NOTE: EXISTING TREES ARE TEARING--TREE LEAVES ARE STOPPING UP ROOF DRAINS FORMERLY GR-20000032 | |||
| FM-200124098 /01 3/20/03 BALLOU BOILER MAINTENANCE 1) BOILER WATER TREATMENT SERVICES TRICON OF WASHINGTON INC. POC: THOMAS PICKETT - 698-1750 | |||
| FM-200121008 01 3/25/03 BALLOU BOILER ROOM REPLACE (1) ONE HOT WATER CIRCULATING PUMP THAT SUPPLIES THE HEATING TO AUTO SHOP. INFO: WORTHINGTON PUMP: SER#AZ10869 IMP. DIA. 6 3/4 A PUMP-1 1/2 LLR7 NOTE: REPLACEMENT NEEDED - WEAR AND TEAR. | |||
| FM-200121007 01 3/25/03 BALLOU BOILER ROOM SPOT WELD (2) TWO 5 INCH METAL PLATES ON THE SUPPLY AND RETURN CONDENSER A/C LINES. NOTE: NO INSTALLATION ON ALL THE PIPING, PLATES ARE NEEDED TO COVER EXITING HOLES. CODE A- CLEAR FOR REPAIRS AS OF 10/24/01 (SG) FOR CEB. | |||
| FM-200125642 /01 3/25/03 BALLOU BOILER ROOM REPLACE #1 HOT WATER (MAIN) CIRCULATING PUMP. INFO: BELL & GOSSETT SIZE 185011, SERIAL # 1664615 I.D. #L19. NOTE: THIS PUMP SUPPLIES HEAT TO THE MAIN BUILDING (FOR HEATING ONLY). | |||
| FM-200125785 /01 3/25/03 BALLOU BOILER ROOM PM A/C CHILLER. | |||
| FM-200124425 01 3/25/03 BALLOU BOILER ROOM REPLACE COOLING TOWER. TOWER IS DETERIORATED AND LEAKS BADLY. | |||
| FM-200115291 01 3/25/03 BALLOU BOILER ROOM 1. ASBESTOS ASSESSMENT REQUIRED. 2. BOILER #4 CLEAVER BROOKS PACKAGED: TUPE REPLACEMENT. REPLACE ENTIRE INTERIOR FIRE TUBES ON #4 BOILER (79 FIRE TUBES) BOILER INFO: CLEAVER BROOKS MOD. #760-125A, SER. #L47171. ASBESTOS CODE A - CLEAR FOR REPAIR ON 07/20/01. | |||
| FM-200100842 01 3/25/03 BALLOU ROOF TOP REPAIR OR REPLACE ROOF TOP EXHAUST FAN. MOD. UNCLOSED MOTOR, 1-1/2 HP, FRAM 184, TYPE H, VOLTS 208/440, SERIAL NO. 1015-00-263, RPM 1500-1800. HC-20000259 | |||
| FM-200210463 02 3/26/03 Ballou Boiler Room Replacing condenser line on cooling system. | |||
| FM-200201815 02 3/26/03 BALLOU BOILER ROOM 1. ASBESTOS ASSESSMENT REQUIRED. 2. RE-INSULATE AND RESET FIRE DOORS ON BOILER S #1, #2 & #3. INFO: BOILERS HOT WATER PACIFIC STEEL. ASBESTOS CODE A-CLEAR FOR REPAIR ON 1/29/02 BY HORNE ENGINEER: EDWARD RODRIGUEZ |