Closed Repair Requests: October 2002
See Also: All Closed Repair Requests at Kramer Middle School
October 2002 Summary
Detailed Reports
| Description | Open Date | Close Date | Time Elapsed |
|---|---|---|---|
| FM-200213979 02 10/10/02 Kramer Doors Throughout Realign and/or adjust the following doors: Auditorium door, front exit door and side door is out of alignment; inside office door is not operating properly; the doors to rooms 3, 21, 303, 315 & 317 need adjustment; adn the cafeteria and rear exit doors are out of alignment. Asbestos Code A - Abated and cleared for repairs on 08/19/02. DCPS Safety - Leroy Minton Jr (RG 08/20/02) | |||
| FM-200209071 02 10/10/02 Kramer ****Urgent**** 1. Asbestos Assessment Reqd. 1st Floor Gym/Girls' Locker Room 2. The water leak was repaired, however, we have found a weak spot and a water leak on the pipe needs to be repaired. Asbestos Code A - Clear for repairs on 06/06/02. Horne Engineering - Sheryll James (RG 06/06/02) | |||
| FM-200209072 02 10/10/02 Kramer 1. Asbestos Assessment Reqd. 1st Floor Gym Stairwell #8 2. The 5th step from the top on stairwell #8 needs repair or replacement [safety hazard]. Asbestos Code A - Clear for repairs on 06/06/02. Horne Engineering - Sheryll James (RG 06/06/02) |
| Description | Open Date | Close Date | Time Elapsed |
|---|---|---|---|
| FM-200218991 02 10/9/02 Kramer M.S Routine Work 1. Check chemical level 2. Added water to pools 3. Back wash filters | |||
| FM-200207892 02 10/9/02 Kramer Ground fl. Computer room Repair leaks on carrier split a/c unit. Unit has 2 leaks in it ad is freezing. up. | |||
| FM-200218122 02 10/9/02 Kramer 1st Floor Room 103 Classroom door needs to be rekeyed, as well as the inside door. | |||
| FM-200213978 02 10/9/02 Kramer Stairwell doors needs latch replacement; and the teachers' lounge needs a turn-style lock placed on it. | |||
| FM-200101127 01 10/10/02 KRAMER ASBESTOS ASSESSMENT THROUGHOUT PLASTER WALLS AND CEILING NOTE: AREAS DAMAGED DUE TO DRAIN STOPPAGE ON ROOF LEAK, DRAIN HAS BEE UNSTOPPED AND ROOF FIXED MT-20001713 ASB MGR. ADDED - ORIGINAL INITIATED 1/12/01 (FJ) ASBESTOS CODE A - CLAER FOR REPAIRS 4/9/01 | |||
| FM-200213286 02 10/10/02 (Kramer) !!!!!EMERGENCY!!!!! Cafeteria: Burning chemical smell and sparks coming from wall outlet. Outlet appears to be melting. | |||
| FM-200205376 02 10/10/02 Kramer School 21 grass cuts for the summer | |||
| FM-200113603 01 10/10/02 KRAMER ROOF 1) Q STREET SIDE DRAIN STOPPED UP | |||
| FM-200206993 02 10/10/02 Kramer Middle School Basement Stairwell - South East Side 1) 3 inch drain backing up, 4 inches of water is in stairwell already. | |||
| FM-200206502 02 10/10/02 Kramer 2nd & 3rd Floors/Corridors 2nd floor & 3rd floor lights are not working around the exit signs. [Poses a possible fire-code violation] | |||
| FM-200217177 02 10/11/02 Kramer 2nd Floor Rooms 205 & 207 Repair and adjust lock on door to 205 to the other side; and rekey lock on door to room 207. | |||
| FM-200220058 /02 10/25/02 Kramer Room 21 and cafeteria Room 21 and kitchen storeroom needs to be re-keyed. |